Page 103 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 103
SEcTION: 12 HORIZONTAL CIRCULATION ELEMENTS SEcTION: 12 HORIZONTAL CIRCULATION ELEMENTS
A minimum width of 1.5 meter shall be free of 12.3.1.5 Internal Corridors:
obstruction on either sides of each Kiosk.
The minimum clear width of internal corridors between
The maximum length of continued kiosks shall be rooms in residential apartments (flats) and offices shall
6.0 meters. be 1.2 meters. (fIgure-36)
≤ 1.8 m
Kiosk-1
≤ 6.0m
Kiosk-2 Apartment
≥1.2 m
≥ 1.5m ≥1.2
m
Adjacent Adjacent
Construction ≥3.0m Kiosk-3 ≥3.0m Construction
Corridor Width Corridor Width
Figure-35 Kiosk Provision within Corridors Public ≥1.8 m
Corridor
c) Hotels and Office Buildings:
1.8 meter with rooms on both sides. Apartment
1.5 meter with rooms on one side.
12.3.1.3 Educational Types:
Figure-36 Internal Corridor Minimum Width
Schools, Institutes and Universities:
3 meters with classes on both sides.
12.3.1.6 Elevator Lobby:
2.4 meters with classes on one side.
The minimum clear un-obstructed width of an elevator
12.3.1.4 Public Buildings, other than the ones mentioned above: lobby shall be 2.4 meters but should not be less than the
corridor width leading to the area. (figure -37)
These will vary according to their function and should not
be less than 2.4 meters width.
102 103