SEcTION: 12  HORIZONTAL CIRCULATION ELEMENTS  SEcTION: 12  HORIZONTAL CIRCULATION ELEMENTS



 12.4  FIRE-EScAPE ROUTES TO EXITS  12.5  GLAZED ARcADES

 12.4.1   Long corridors shall be sub-divided by fire/smoke doors if the   Glazed arcades are routes intended exclusively for pedestrians.
 building is not completely sprinkler protected.  Arcades can be of multiple uses (retail sales, mixed sectors etc.) therefore,
                     facilities that will attract customers outside normal business hours should
 12.4.2  Corridors must be enclosed  in fire resistant construction, in
 which all doors are fire resistant, self-closing and fitted with   be encouraged.
 smoke seals as per E.H.S. requirements.   No elements  shall  obstruct  pedestrian  movements  within  the arcade,
                     which shall be continous in width and level with the adjacent building
 12.4.3  Walls and ceilings shall not be lined with flammable materials.
                     arcade.  Walkways shall follow the requirements for people with disability,
 12.4.4  Escape corridors should not contain sources of ignition or   which shall conform to the Authority’s related code.
 obstructions to the flow of people (e.g. photocopiers and   The Glazed arcade is a building type that is both interesting and popular
 vending machines).  A minimum clear width of 1.0 meter shall be   in contemporary architecture. Arcades may be on a single level, slope
 maintained.         gently to follow the contours of the site, or have a split-level arrangement

 12.4.5  An interior corridor does not become part of an exit until it is   to change the walkway levels. (figure -38)
 enclosed as a fire compartment.
                                       Natural Lighting
 12.4.6  The slope of a walking surface in the direction of travel shall not
 exceed 5%.                                              Glazed
 12.4.7  Walking surfaces shall be slip resistant under foreseeable
 conditions. The walkway surface for egress shall be slip resistant.

 12.4.8  Common corridors, dead end and travel distance limits by type of
 occupancy and shall be as per E.H.S. regulations.








                               Retail                            Retail





                                 Figure-38     Glazed Arcade Double-Level





 106                                                                     107