SEcTION: 12  HORIZONTAL CIRCULATION ELEMENTS  SEcTION: 12  HORIZONTAL CIRCULATION ELEMENTS



  A minimum width of 1.5 meter shall be free of   12.3.1.5  Internal Corridors:
 obstruction on either sides of each Kiosk.
                                  The minimum clear width of internal corridors between
  The maximum length of continued kiosks shall be   rooms in residential apartments (flats) and offices shall
 6.0 meters.                      be 1.2 meters. (fIgure-36)


 ≤ 1.8 m


 Kiosk-1
 ≤ 6.0m

 Kiosk-2                                                 Apartment
                                         ≥1.2  m

 ≥ 1.5m                                           ≥1.2
                                                  m
 Adjacent  Adjacent
 Construction  ≥3.0m  Kiosk-3  ≥3.0m  Construction
 Corridor Width  Corridor Width




 Figure-35   Kiosk Provision within Corridors  Public        ≥1.8 m
                                      Corridor
 c)  Hotels and Office Buildings:
  1.8 meter with rooms on both sides.             Apartment
  1.5 meter with rooms on one side.

 12.3.1.3  Educational Types:
                                     Figure-36   Internal Corridor Minimum Width
 Schools, Institutes and Universities:
  3 meters with classes on both sides.
                           12.3.1.6  Elevator Lobby:
  2.4 meters with classes on one side.
                                  The minimum clear un-obstructed width of an elevator
 12.3.1.4  Public Buildings, other than the ones mentioned above:  lobby shall be 2.4 meters but should not be less than the
                                  corridor width leading to the area. (figure -37)
    These will vary according to their function and should not
 be less than 2.4 meters width.