SEcTION  12  HORIZONTAL CIRCULATION ELEMENTS  SEcTION: 12  HORIZONTAL CIRCULATION ELEMENTS







 12.1  ROUTE AccESS TO ThE SITE  12.3 cORRIDORS

 12.1.1   Provision of points of ingress and egress shall be located to the   12.3.1  Corridors shall be clear from any obstruction, such as door
 satisfaction of the Authority.  opening or copy machine (figure -34). The minimum clear un-
                            obstructed width for public corridors shall be as follows:
 12.1.2   All parts of the site to which vehicles may have access shall be
 hard surfaced and drained to the satisfaction of the Authority.
                                              Water Fountain  Door Fully Open
 12.1.3   All access locations and curb crossings shall require the approval
 of the Authority.  Public roadways carrying heavy volume of traffic   Door
 shall not be used for access unless there is no other practical   A
                                                        Corridor  Width  Exit  0.18 m  Exit
 alternative.                           Max. 0.18 m             Max.
 12.1.4   The access routes for fire fighting shall be provided.  Access
                   Door
                    B
 12.1.5   The site and all improvements thereon shall be maintained in   Door A and B Not Allowed
 clean and tidy conditions.
                                  Figure-34   Corridor Clear Width

 12.2  ROUTE AccESS TO ThE BUILDING

 12.2.1   Public and service entrances shall be clearly located and   12.3.1.1  Residential Types:
 identified.                      a)  1.8 meter with rooms on both sides.
                                  b)  1.5 meter with rooms on one side.
 12.2.2  Location of the car parking to main entrance shall be clearly
 identified.
                           12.3.1.2  Commercial Types:
 12.2.3  Location of parking for people with disability from the main
 entrance shall be identified.    a)  In general 3.0 meters
 12.2.4  Identification of loading area location.   b)  In case of providing kiosks along the corridor of any
                                     Commercial Building:
                                     The  maximum  kiosk  width  shall  be  1.8  meter.
                                       (figure -35)

                                     The minimum corridor width between the kiosks
                                       and the adjacent shop or construction shall be 3.0
                                       meters.




 100                                                                     101