Page 39 - Building Regulation and Design Guidelines - Structural (Grey Code)
P. 39

SECTION: 2    STRUCTURAL DESIGN GUIDELINES – BUILDING STRUCTURES




                         elevations and openings are to be submitted. Detailed sectional plan
                         and sectional elevations for lift and core walls showing the reinforcement
                         in the walls, around openings, corner bars, spandrel beam details and
                         wherever is necessary to be provided.
                     7.   Floating columns/walls and transfer beams/slabs structures:
                         The sizes of floating elements along with their locations are to be marked
                         in  plan drawing.  Sectional  elevation  showing the  columns/walls  below
                         and above the transfer structure has to be drawn. The transfer structure
                         sections shall include the reinforcement details of all members and
                         connections and any special provisions may be required by the design or
                         construction.
                     8.   Staircases:
                         Detailed plan, sections and reinforcement drawings for staircase are to
                         be submitted.
                     9.   Swimming pools:
                         Detailed GA plan and sections for swimming pool indicating the levels
                         and supporting arrangement including floating columns, if any. Adequate
                         sections are to be drawn to show reinforcement in base slab, walls, deck
                         slab, etc.
                    10.   Non structural architectural features:
                         The architectural features constructed from concrete or any other materials
                         shall meet all the relevant stability, durability and constructability
                         requirements.
                     11.   All the structural drawings shall have a standard title block containing
                         the project name, the plot number, BU’s name, client name, name of the
                         lead consultant, drawing title, key plan identifying the area relevant to the
                         drawing subject, full record of different revisions, etc.
                    12.   All the structural drawings shall be cross referenced as much as possible.
                    13.   All  the  structural  drawings  shall  be  signed and stamped in  standard
                         location of the drawings. Typical space shall be left for CED stamping. If
                         applicable, all the submitted drawings shall be signed and stamped by the
                         third party consultant.
                    14.   All the structural drawings required to be approved from CED shall be
                         combined together in PDF binder and shall be properly oriented as well
                         as arranged in order.





          76