Page 196 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 196

SEcTION: 17  SANITATION REQUIREMENTS  SEcTION: 17  SANITATION REQUIREMENTS



 d)  Health Buildings:  17.3.2   Requirements for uses not specifically listed herein shall be
  Hospitals:  sanitary  provisions  at  rates  not  less  than   determined by the Authority, based upon the requirements for
 mentioned in below table-22.  comparable uses and upon particular characteristics of the use.
 Appliances  Facility per Male Staff  Facility per Female Staff  17.3.3   The entry shall be laid out properly.
 WCs and Washbasins   1 per 4  1 per 4
                     17.3.4   All  passageways  or  corridors  should  have  a  minimum  width
 Table-22    Sanitation Provisions for Hospitals  of  1.2meters.

 e)  Cultural Buildings:  17.3.5   The minimum dimensions of stalls shall be 0.9 x 1.25 meters with
  Theatres  and  Banquet  Halls:  sanitary  provisions  as   outward door opening and 0.9 X 1.50 meters with inward door
 mentioned in below table-23.  opening.

 Appliances  Facility per Male Staff  Facility per Female Staff  17.3.6   The working parts of at least one of each type of dispenser,
 WCs and    1 up to 250, plus 1 for Every    2 up to 75, plus 1 for Every   receptacle and vender (coin slots, push buttons, dispenser
 Washbasins   Additional 500 or Part Thereof.  Additional 50 or Part Thereof.  openings, etc) shall be located 1.0 meter above the floor finish
  2 up to 100,  plus 1 for Every   level.
 Urinals
 Additional 50 or Part Thereof.
                     17.3.6   Waste receptacles are recommended to be recessed into the wall,
 Table-23    Sanitation Provisions for Theatres and Banquet Halls
                            out of everyone’s way.
  Cinemas: sanitary provisions at rates not less than
 mentioned in below table-24.  17.3.7   In addition to general lighting, task lighting shall be provided for
                            each functional area in the sanitary facility.
 Appliances  Facility per Male Staff  Facility per Female Staff
                     17.3.8   The doors to adjacent female and male washrooms shall not be
 WCs and    1 up to 250, plus 1 for Every    2 up to 100, plus 1 for Every
 Washbasins  Additional 500 or Part Thereof.  Additional 100 or Part Thereof.  next to each other as this is psychologically disturbing and does
 2 up to 200, males plus 1 for Every   not offer privacy. Doors shall be self closing wherever possible.
 Urinals
 Additional 100 or Part Thereof.
                     17.3.9   The use of common toilets in case both sexes are employed is
 Table-24    Sanitation Provisions for Cinamas  prohibited.
 f)  Industrial Building:
  Factories and Warehouses: sanitary provisions at rates not
 less than mentioned in below table-25.  17.4  SANITARY FAcILITIES FOR PEOPLE WITh DISABILITY
 Appliances  Facility per Male Staff  Facility per Female Staff  A  WC  compartment  for  general  use  by people with disability  shall  allow
 1 per 25, or Part Thereof.     for  a  frontal  or  lateral  transfer  from  the  wheelchair,  with  space  for
 WCs and   1 per 25,
 Washbasins  For over 100, add at rate of    or Part Thereof.  the attendant to assist. The details in accordance with Authority’s related
 1 per 40 urinals  also provided.  code.
 Table-25     Sanitation Provisions for Factories and Warehouses


 194                                                                     195