Page 192 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 192

SEcTION  17  SANITATION REQUIREMENTS  SEcTION: 17  SANITATION REQUIREMENTS







 17.1  GENERAL REQUIREMENTS  17.2  RESIDENTIAL BAThROOM AND LAVATORY


 17.1.1   Every habitable building must include provisions for sanitary   17.2.1   The minimum areas for bathrooms and toilets shall be as
 facilities, unless otherwise permitted by the Authority.  These   mentioned on section-8.
 facilities must include the provision of at least one toilet.
                     17.2.2   Bathrooms and toilets without ventilating windows shall be
 17.1.2   Hot and cold water services shall be provided to washbasins.  replaced by ventilating ducts. The air inlet and exhaust should be
                            well designed.
 17.1.3   Trapped floor gullies or drainage channels shall be provided in
 ablutions to enable all areas to be washed down, cleaned and   17.2.3   Light  switches,  electrical  outlets,  thermostats,  and  other
 drained.                   environmental controls shall be in accessible locations.
 17.1.4   All finished internal surfaces of ablutions shall be non-absorbent   17.2.4   It is convenient that bathrooms and toilets are adjacent to the
 and cleanable.             served spaces. (figure -75)

 17.1.5   The construction of cubicles, wherever provided shall not impede
 the free movement of air within ablution buildings.

 17.1.6   Water  closets,  urinals  and  washbasins  shall  have  a  smooth
                                                          Living Room
 and readily cleanable non-absorbent surface.  They shall be
 constructed and fitted to discharge through an effective trap   corridor
 of suitable dimensions and thence without storage to a pipe or
 drain. The flushing apparatus for a water closet or urinal shall be
 capable of effective cleaning of the receptacle.
                            Privacy
 17.1.7   ventilation pipes shall be of adequate size for their purpose but
 not less than 0.05 meter internal diameter. They shall be carried
 upwards to a certain height and be positioned in order not to
                            Bedroom          Bathroom
 transmit foul air odor.
                                                            Bedroom
 17.1.8   Permission must be obtained from the Authority for the location
 of any manhole within any building.  Where permission is given,
 such manholes must have a double sealed screwed down cover.

                                  Figure-75     Bathroom Convenient Location