Page 195 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 195

SEcTION: 17  SANITATION REQUIREMENTS                                                SEcTION: 17  SANITATION REQUIREMENTS



                            d)  Health Buildings:                                                        17.3.2   Requirements for uses not specifically listed herein shall be
                               Hospitals:  sanitary  provisions  at  rates  not  less  than                    determined by the Authority, based upon the requirements for
                                 mentioned in below table-22.                                                   comparable uses and upon particular characteristics of the use.
                       Appliances      Facility per Male Staff  Facility per Female Staff                17.3.3   The entry shall be laid out properly.
                   WCs and Washbasins       1 per 4             1 per 4
                                                                                                         17.3.4   All  passageways  or  corridors  should  have  a  minimum  width
                             Table-22    Sanitation Provisions for Hospitals                                    of  1.2meters.

                            e)  Cultural Buildings:                                                      17.3.5   The minimum dimensions of stalls shall be 0.9 x 1.25 meters with
                               Theatres  and  Banquet  Halls:  sanitary  provisions  as                        outward door opening and 0.9 X 1.50 meters with inward door
                                 mentioned in below table-23.                                                   opening.

                   Appliances     Facility per Male Staff  Facility per Female Staff                     17.3.6   The working parts of at least one of each type of dispenser,
                    WCs and      1 up to 250, plus 1 for Every    2 up to 75, plus 1 for Every                  receptacle and vender (coin slots, push buttons, dispenser
                   Washbasins   Additional 500 or Part Thereof.  Additional 50 or Part Thereof.                 openings, etc) shall be located 1.0 meter above the floor finish
                                 2 up to 100,  plus 1 for Every                                                 level.
                     Urinals
                                Additional 50 or Part Thereof.
                                                                                                         17.3.6   Waste receptacles are recommended to be recessed into the wall,
                      Table-23    Sanitation Provisions for Theatres and Banquet Halls
                                                                                                                out of everyone’s way.
                               Cinemas: sanitary provisions at rates not less than
                                 mentioned in below table-24.                                            17.3.7   In addition to general lighting, task lighting shall be provided for
                                                                                                                each functional area in the sanitary facility.
                   Appliances     Facility per Male Staff  Facility per Female Staff
                                                                                                         17.3.8   The doors to adjacent female and male washrooms shall not be
                    WCs and      1 up to 250, plus 1 for Every    2 up to 100, plus 1 for Every
                   Washbasins  Additional 500 or Part Thereof.  Additional 100 or Part Thereof.                 next to each other as this is psychologically disturbing and does
                              2 up to 200, males plus 1 for Every                                               not offer privacy. Doors shall be self closing wherever possible.
                     Urinals
                               Additional 100 or Part Thereof.
                                                                                                         17.3.9   The use of common toilets in case both sexes are employed is
                             Table-24    Sanitation Provisions for Cinamas                                      prohibited.
                            f)  Industrial Building:
                               Factories and Warehouses: sanitary provisions at rates not
                                 less than mentioned in below table-25.                             17.4  SANITARY FAcILITIES FOR PEOPLE WITh DISABILITY
                   Appliances      Facility per Male Staff  Facility per Female Staff                    A  WC  compartment  for  general  use  by people with disability  shall  allow
                                 1 per 25, or Part Thereof.                                              for  a  frontal  or  lateral  transfer  from  the  wheelchair,  with  space  for
                    WCs and                                   1 per 25,
                   Washbasins   For over 100, add at rate of    or Part Thereof.                         the attendant to assist. The details in accordance with Authority’s related
                               1 per 40 urinals  also provided.                                          code.
                      Table-25     Sanitation Provisions for Factories and Warehouses