SEcTION  17  SANITATION REQUIREMENTS                                       SEcTION: 17  SANITATION REQUIREMENTS







                17.1  GENERAL REQUIREMENTS                                                          17.2  RESIDENTIAL BAThROOM AND LAVATORY


                     17.1.1   Every habitable building must include provisions for sanitary              17.2.1   The minimum areas for bathrooms and toilets shall be as
                            facilities, unless otherwise permitted by the Authority.  These                     mentioned on section-8.
                            facilities must include the provision of at least one toilet.
                                                                                                         17.2.2   Bathrooms and toilets without ventilating windows shall be
                     17.1.2   Hot and cold water services shall be provided to washbasins.                      replaced by ventilating ducts. The air inlet and exhaust should be
                                                                                                                well designed.
                     17.1.3   Trapped floor gullies or drainage channels shall be provided in
                            ablutions to enable all areas to be washed down, cleaned and                 17.2.3   Light  switches,  electrical  outlets,  thermostats,  and  other
                            drained.                                                                            environmental controls shall be in accessible locations.
                     17.1.4   All finished internal surfaces of ablutions shall be non-absorbent         17.2.4   It is convenient that bathrooms and toilets are adjacent to the
                            and cleanable.                                                                      served spaces. (figure -75)

                     17.1.5   The construction of cubicles, wherever provided shall not impede
                            the free movement of air within ablution buildings.

                     17.1.6   Water  closets,  urinals  and  washbasins  shall  have  a  smooth
                                                                                                                                              Living Room
                            and readily cleanable non-absorbent surface.  They shall be
                            constructed and fitted to discharge through an effective trap                                  corridor
                            of suitable dimensions and thence without storage to a pipe or
                            drain. The flushing apparatus for a water closet or urinal shall be
                            capable of effective cleaning of the receptacle.
                                                                                                                Privacy
                     17.1.7   ventilation pipes shall be of adequate size for their purpose but
                            not less than 0.05 meter internal diameter. They shall be carried
                            upwards to a certain height and be positioned in order not to
                                                                                                                Bedroom          Bathroom
                            transmit foul air odor.
                                                                                                                                                Bedroom
                     17.1.8   Permission must be obtained from the Authority for the location
                            of any manhole within any building.  Where permission is given,
                            such manholes must have a double sealed screwed down cover.

                                                                                                                      Figure-75     Bathroom Convenient Location








          190                                                                                                                                                191