 g)  The  minimum  area  of  hotel  serviced  apartments,   Regarding  its dimensions, the doors, the
 excluding bathroom and entrance lobby, shall be as   locations, the designs of the furniture’s and
 followings:                            location of the electrical switches, the minimum
   For bedroom: 12.0 square meters.    maneuvering space to be provided shall be 1.5
                                        meter.
   For studio:18.0 square meters.
                                      c)  The room should have a bathroom in accordance
 h)  Adequate natural lighting should be provided at   with  Authority’s  related  code,  regarding  the
 the main entrance, corridors, staircases, rooms and   toilet  seat, bathtub, washbasin,  cabinets,
 halls.                                 mirror, the type of flooring, the size of the doors,
                                        the location of the bathroom accessories and
 i)  Air conditioning shall be provided for all rooms,
 halls, restaurants and entrance lobbies.  the position of the bars and handles that do not
                                        obstruct the movement within bathroom.
 j)  Self-illuminating signs must be placed in all the   d)  Room to have an emergency exit leading directly
 corridors, staircases, hallways, reception and   outside the building or to a balcony. Means of
 places that are used by the public, in case of fire.
                                        safety and security shall be provided for various
 k)  Fire  extinguishers should be positioned in visible   categories of people with disability.
 and accessible places, with signs indicating where   e)  Car parking lots to be as near as possible to the
 they are to be found. No materials or obstacles   main entrances and shall be in accordance with
 should be allowed to hamper the use of the   Authority’s related code.
 extinguishers.

 l)  Building architectural plan drawing shall be placed
 behind the door of each guest’s room, indicating the
 fire escape exits, in order to ensure safe evacuation
 in case of fire hazard.

    The minimum facilities provided to people with
 disability, in hotels that are (3) star and above, shall
 be as follows:
 a)  One hotel room, if the total number of rooms and
 suites is less than 100. Two rooms if the number
 is more than 100 and they should be located on
 the first floor.
 b)  The room shall be in accordance with Authority’s
 related code and International Standard
 Requirements for people with disability.