SEcTION: 16 BUILDING OR DEVELOPMENT TYPES SEcTION: 16 BUILDING OR DEVELOPMENT TYPES
16.3.3.8 Installation of public telephone booth and ATM
machines are recommended for emergency purposes.
16.3.3.9 The car service and wash stations must be equipped
with devices and equipment, which are used
for draining and purifying water, such as sand
sedimentation rooms, oil traps and pumps to purify R
the water before connecting it to the decomposition R 10.0 10.0
(septic) tanks or to the public drainage network.
16.3.3.10 Air and water hoses for the customer shall be 45.0° 20.0 m 45.0°
provided. road
6.0 m
6.0 m
16.3.3.11 Parking spaces shall be provided, in accordance with
section -15 of these regulations. Gas Station with Fuel Pump Islands Obliquely Angled (mainly for one-way traffic)
16.3.3.12 The consultant must submit a site plan of the station
showing: (figure -74) 45.0°
a) The proposed entrances and exits, according to R 10.0
the existing speed limit on the road in which the 6.0 m
station is to be located.
b) All the existing elements that are within a distance
of 500.0 meters before and after the proposed 15.0 m
station, including traffic signs, lampposts, trees, R≥ 10.0
inspection chambers, pump rooms and branch Front Corner Boundary
electricity stations.
Road
c) The direction of the traffic, number of road lanes 45.00°
25.0 m
and speed limit. 6.0 m
Road
Access to Corner Gas Station
Figure-74 Access to Gas Station