                                   g)  The  minimum  area  of  hotel  serviced  apartments,                                 Regarding  its dimensions, the doors, the
                                      excluding bathroom and entrance lobby, shall be as                                    locations, the designs of the furniture’s and
                                      followings:                                                                           location of the electrical switches, the minimum
                                        For bedroom: 12.0 square meters.                                                   maneuvering space to be provided shall be 1.5
                                                                                                                            meter.
                                        For studio:18.0 square meters.
                                                                                                                         c)  The room should have a bathroom in accordance
                                   h)  Adequate natural lighting should be provided at                                      with  Authority’s  related  code,  regarding  the
                                      the main entrance, corridors, staircases, rooms and                                   toilet  seat, bathtub, washbasin,  cabinets,
                                      halls.                                                                                mirror, the type of flooring, the size of the doors,
                                                                                                                            the location of the bathroom accessories and
                                   i)  Air conditioning shall be provided for all rooms,
                                      halls, restaurants and entrance lobbies.                                              the position of the bars and handles that do not
                                                                                                                            obstruct the movement within bathroom.
                                   j)  Self-illuminating signs must be placed in all the                                d)  Room to have an emergency exit leading directly
                                      corridors, staircases, hallways, reception and                                        outside the building or to a balcony. Means of
                                      places that are used by the public, in case of fire.
                                                                                                                            safety and security shall be provided for various
                                   k)  Fire  extinguishers should be positioned in visible                                  categories of people with disability.
                                      and accessible places, with signs indicating where                                 e)  Car parking lots to be as near as possible to the
                                      they are to be found. No materials or obstacles                                       main entrances and shall be in accordance with
                                      should be allowed to hamper the use of the                                            Authority’s related code.
                                      extinguishers.

                                   l)  Building architectural plan drawing shall be placed
                                      behind the door of each guest’s room, indicating the
                                      fire escape exits, in order to ensure safe evacuation
                                      in case of fire hazard.

                                      The minimum facilities provided to people with
                                      disability, in hotels that are (3) star and above, shall
                                      be as follows:
                                      a)  One hotel room, if the total number of rooms and
                                        suites is less than 100. Two rooms if the number
                                        is more than 100 and they should be located on
                                        the first floor.
                                      b)  The room shall be in accordance with Authority’s
                                        related code and International Standard
                                        Requirements for people with disability.