Page 169 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 169

SEcTION: 16  BUILDING OR DEVELOPMENT TYPES                                          SEcTION: 16  BUILDING OR DEVELOPMENT TYPES



                            16.3.1.5  Kitchen Requirements:                                                            order to maintain the building elevation presentable.
                                                                                                                       The chimneys shall rise to a maximum height of 3.0
                                   a)  The required kitchen shall be constructed of fire                               meters above the building roof. They should be treated
                                      resistant materials and shall comply with standards                              with environmental protection filtering kit to prevent
                                      required by the Authority.
                                                                                                                       hazardous effects on the neighbors and /or ruin the
                                   b)  Floors and walls shall be impervious to moisture                                general image.
                                      and capable of being cleaned by washing down.                             16.3.1.7  Cold stores and freezers shall be provided with
                                      Floors shall be hard- surfaced, non-absorbent and                                thermometers for taking temperature readings. Such
                                      adequately drained. They shall be constructed with                               thermometer shall be fitted in such a way as to allow
                                      waterproof, non-absorbent washable materials                                     taking readings externally. Doors should be open-able
                                      without fissures or crevices.
                                                                                                                       from both sides, inside and outside.
                                   c)  Walls shall be tiled to a height of 2.1 meters above                     16.3.1.8  The minimum area of an establishment is as follows:
                                      floor level with ceramic tiles. Internal walls shall
                                      be smooth, waterproof, resistant to fracture, light                                  Activity     Minimum Area (square meters)
                                      colored and readily cleanable.
                                                                                                                          Greengrocer             20
                                   d)  Drains shall incorporate grease and pea (rice) traps                                Butcher                15
                                      and interceptors.
                                                                                                                          Soft drinks             10
                                   e)  Working surfaces for preparation of food are to be                                             15 square meters the display area shall
                                      of stainless steel or other approved impervious                                       Mills     be separate from the preparation area
                                      material to facilitate cleaning and maintenance of                                   Roastery               25
                                      hygienic conditions.
                                                                                                                         Super Market  200 square meters, 50 square meters
                                   f)  Mechanical extraction with exhaust hoods and fans                                                     of them as a storage
                                      shall be provided to all areas involving cooking                                      Grocer                12
                                      activities i.e. stoves, gas rings, tan doors etcز
                                                                                                                   Table -16     The Minimum Areas for Food Establishments
                                   g)  Gas pipes to cookers, rings etc., and shall be laid
                                      in an approved manner with approved materials                             16.3.1.9  The facilities should have a provision for people with
                                      i.e. copper or steel tubing, permanent joints, and                               disability as per Authority’s related code
                                      minimum flexible hose.                                                           a)  Restaurants and eating spaces should be as

                                   h)  Kitchens shall be fitted with recommended fire                                     accessible as possible to a wheelchair user.
                                      extinguishers as decided by the Fire Officer.                                    b)  In self-service restaurants, tray slides and counters
                                                                                                                          should be mounted at a minimum height of 0.9 meter
                                   i)  Layout and construction details of any temporary
                                      canteen required during the period of construction                                  from the finished floor level. Food shelves should be
                                      shall be approved by the Authority.                                                 mounted at a maximum height of 1.2 meter.

                            16.3.1.6  The chimneys that are installed in bakeries, restaurants                         c)  Cantilevered tables or tables with straight legs at
                                   and roasteries shall be located on the rear side of                                    each corner are preferable to central pedestals that
                                   the plot or through the building shafts and ducts, in                                  might restrict wheelchair access.


          168                                                                                                                                                169