Page 170 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 170

SEcTION: 16  BUILDING OR DEVELOPMENT TYPES  SEcTION: 16  BUILDING OR DEVELOPMENT TYPES



 16.3.1.5  Kitchen Requirements:   order to maintain the building elevation presentable.
                                   The chimneys shall rise to a maximum height of 3.0
 a)  The required kitchen shall be constructed of fire   meters above the building roof. They should be treated
 resistant materials and shall comply with standards   with environmental protection filtering kit to prevent
 required by the Authority.
                                   hazardous effects on the neighbors and /or ruin the
 b)  Floors and walls shall be impervious to moisture   general image.
 and capable of being cleaned by washing down.   16.3.1.7  Cold stores and freezers shall be provided with
 Floors shall be hard- surfaced, non-absorbent and   thermometers for taking temperature readings. Such
 adequately drained. They shall be constructed with   thermometer shall be fitted in such a way as to allow
 waterproof, non-absorbent washable materials   taking readings externally. Doors should be open-able
 without fissures or crevices.
                                   from both sides, inside and outside.
 c)  Walls shall be tiled to a height of 2.1 meters above   16.3.1.8  The minimum area of an establishment is as follows:
 floor level with ceramic tiles. Internal walls shall
 be smooth, waterproof, resistant to fracture, light   Activity  Minimum Area (square meters)
 colored and readily cleanable.
                                      Greengrocer             20
 d)  Drains shall incorporate grease and pea (rice) traps   Butcher  15
 and interceptors.
                                      Soft drinks             10
 e)  Working surfaces for preparation of food are to be   15 square meters the display area shall
 of stainless steel or other approved impervious   Mills  be separate from the preparation area
 material to facilitate cleaning and maintenance of   Roastery  25
 hygienic conditions.
                                     Super Market  200 square meters, 50 square meters
 f)  Mechanical extraction with exhaust hoods and fans    of them as a storage
 shall be provided to all areas involving cooking   Grocer    12
 activities i.e. stoves, gas rings, tan doors etcز
                               Table -16     The Minimum Areas for Food Establishments
 g)  Gas pipes to cookers, rings etc., and shall be laid
 in an approved manner with approved materials   16.3.1.9  The facilities should have a provision for people with
 i.e. copper or steel tubing, permanent joints, and   disability as per Authority’s related code
 minimum flexible hose.            a)  Restaurants and eating spaces should be as

 h)  Kitchens shall be fitted with recommended fire   accessible as possible to a wheelchair user.
 extinguishers as decided by the Fire Officer.  b)  In self-service restaurants, tray slides and counters
                                      should be mounted at a minimum height of 0.9 meter
 i)  Layout and construction details of any temporary
 canteen required during the period of construction   from the finished floor level. Food shelves should be
 shall be approved by the Authority.   mounted at a maximum height of 1.2 meter.

 16.3.1.6  The chimneys that are installed in bakeries, restaurants   c)  Cantilevered tables or tables with straight legs at
 and roasteries shall be located on the rear side of   each corner are preferable to central pedestals that
 the plot or through the building shafts and ducts, in   might restrict wheelchair access.


 168                                                                     169