Page 182 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 182
SEcTION: 16 BUILDING OR DEVELOPMENT TYPES SEcTION: 16 BUILDING OR DEVELOPMENT TYPES
16.4.2.4 The kindergarten building shall include waiting areas and 16.4.3 NURSERIES
rooms for management staff, teachers, administrators
and supervisors. The areas of these rooms shall match 16.4.3.1 Nurseries shall be located in an area which has been
the number of children enrolled. set aside for nurseries, in accordance with the DCR and
master plan of related business unit.
16.4.2.5 Kindergartens shall have a playground of an area not
less than double the area allocated to classrooms. At 16.4.3.2 Nurseries shall be designed according to the approved
least one third of this area shall be covered, and part of requirements of the Ministry of Education and the
it shall be planted. Toys and recreational facilities shall provisions of these regulations.
be provided for children and shall be maintained and 16.4.3.3 Children sanitary installation requirements shall be as
inspected on regular basis. mentioned on section-17.
16.4.2.6 Kindergartens shall have at least one canteen, and 16.4.3.4 Teachers and employees shall have one lavatory and
multipurpose hall. washbasin per 2 nursery rooms.
16.4.2.7 Children’s sanitary installation requirements shall be as 16.4.3.5 Natural ventilation, lighting and air-conditioning shall
mentioned in section-17. be provided according to Authority standards, for every
16.4.2.8 Teachers and employees shall have one lavatory and part of the building. All windows shall be provided with
washbasin per 10 employees. appropriate curtains.
16.4.2.9 Kindergartens shall have a health clinic that is consists 16.4.3.6 The minimum distance between beds in the nursery
of a minimum of physician room, an examination room rooms shall be 1.0 meter.
and a lavatory. 16.4.3.7 Nursery shall be located on either the ground or first
16.4.2.10 A provision for security/guard post, with minimum floor. It shall include open spaces that can be used for
space area of 6.5 square meters, should be provided. children’s physical activities.
16.4.2.11 The kindergarten building must be independent and 16.4.3.8 The building shall have a room that is used as a clinic with
it shall not include any other educational classes all basic medical equipments and first aid supplies.
belonging to any other academic levels. The classrooms 16.4.3.9 A provision for security/guard post, with minimum space
shall be located on the ground floor level. area of 6.5 square meters, should be provided.