 13.1.12  The minimum clear vertical height from the bottom margin of   13.1.16  The staircase location shall be easily approachable from any part
 the landing finishes to the pedestrian passageway shall be 2.4   of the building, in which the farthest point shall not exceed 30.0
 meters. (figure -45)       meters in distance. (figure -46)
 Suspended Element
                                             E       E

                                             E       E
 ≥ 2.4 m
 Wall

 ≥ 2.4 m  ≥ 0.9 m






 W-Landing width
                                     Figure-46   Staircase Location via User

 W ≥ (1.1 m or 1.5 m) Depending on Building Types  13.1.17  Landing platforms shall at least be 0.9 meter depth if doors swing
 Figure-45   Headroom Measurement  inwards, and 1.5 meter if doors swing outwards. (figure -47)


 13.1.13  The main staircase in residential, commercial and public   Landing  Landing
 buildings must be made of fire resistant material (with the   with  with
 exception of villas). Sufficient natural ventilation and lighting   Inward  Outward
                                                                    Opening
 must be available on staircases, through windows that have   Opening
 direct access to open air, or through ducts and shafts.  ≥ 1.5 m
 13.1.14  The staircases of towers that are more than 10 floors are   ≥ 0.9 m
 exempted from the rule of natural lighting and ventilation. But
 they must be provided with mechanical and electrical ventilation
 and lighting, according to the conditions and specifications of
 E.H.S..                             UP                     UP
 13.1.15  There shall be a protective barrier on the empty side of the   Figure-47   Landing Provision
 staircase  higher than 1.0 meter (rail or balustrade) whose
 minimum height shall  be 0.9 meter, and maximum clearance   13.1.18  Refer to the Authority’s related code for staircases requirements
 among the vertical rods of the stair railing shall be 0.125 meter. In   for people with disability.