SEcTION: 13  VERTICAL CIRCULATION ELEMENTS  SEcTION: 13  VERTICAL CIRCULATION ELEMENTS



 13.2  ELEcTRIc ELEVATORS  13.2.8   Elevators shall be provided with an electric closing system and a
                            warning device that signs on when the maximum load exceeds.
 13.2.1   Elevators shall be provided in buildings that are higher than three   It shall also have an emergency landing system, sufficient
 floors depending upon the building or project requirements
                            mechanical ventilation, and suitable internal lighting.
 13.2.2   For shopping malls higher than one floor, panoramic elevators,   13.2.9   Directional and warning labels shall be posted next to each door
 with 10 person’s capacity are required.
                            inside the elevator showing total permissible weight, smoking
 13.2.3   The following variables are involved in elevator selection:  ban, proper use of elevator in case of fire, prohibiting small
                            children not accompanied by adults to use the system.
 a)  Travel distance.
 b)  Elevator speed.  13.2.10  All elevators shall be checked regularly to ensure proper working
                            order.  The property owner must obtain a yearly certificate
 c)  Elevator capacity: The minimum capacity shall be 4 persons
 per travel.                confirming proper elevator’s functionality from the maintenance
                            company approved by the Authority.
 d)  Building population.
                     13.2.11   In shopping malls comprising of more than one floor, at least
 e)  Number and areas of the floors.
                            one elevator  shall be designed for people with disability in
 13.2.4   For buildings with a tower or corridor style, the installation of the   accordance with International Standards. An electrically operated
 elevators must be centralized.  escalator is not a sufficient replacement to this elevator, except
                            if such escalator provided with an adaptable tread of at least 1.2
 13.2.5   Elevators shall be clearly indicated and be located close to the   meter long, and features necessary for people with disability.
 staircase circulation. In case of mixed use buildings, elevators
 leading to different uses shall be segregated.       13.2.12   An indoor lobby shall be provided for any elevator and shall be
                            equipped with mechanical lighting and ventilation.
 13.2.6   At least one of the elevators shall be allocated for people with
 disability. Refer to Authority’s related code.
 13.2.7   Rooms built at the rooftop to house elevator equipment shall
 satisfy the following:
 a)  Have  dimensions  that  conform  to  the  specifications and
 measurements of the elevator’s manufacturing company.
 b)  Have a good air-conditioning system.
 c)  Have door openings that can be closed securely.

 d)  Operating wires and cables shall be concealed and be made
 from anti rust material.

 e)  Have suitable cover for all moveable parts and components.