Page 96 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 96

SEcTION: 11  BUILDING STORIES /FLOOR TYPES  SEcTION: 11  BUILDING STORIES /FLOOR TYPES



 11.3  MEZZANINE   11.4  ROOFTOP


 That portion of a floor which is an intermediate level placed within   Part of a full floor situated above the Last floor of the building and
 building  floors and having occupy-able space above and below its floor.   normally being used for accommodating elevator machinery, mechanical/
 Its functional use may either be complementary and belonging to the   electrical rooms, water tanks, pergolas, swimming pools and gymnasiums
 ground floor or independent functional use similar to typical floor or may   in addition to services associated with them.
 be used for services.
                     11.4.1   All buildings must feature either some form of sloped roof or
 11.3.1   The mezzanine floor shall be permitted to be used 100%   parapets screening a flat roof.
 independently if it is used as parking space for cars, or as
 extension to the main function of the whole building, which is   11.4.2   A flat roof, if specified, shall be screened with parapets on all
 used for one common purpose.  sides of the building. Parapets shall be at least 1.1 meter in
                            height from average roof floor finished level / FFL. (figure -33)
 11.3.2   The mezzanine floor can be used for commercial purposes that
 are 100% independent, in case of using the ground floor and the
 mezzanine as a Shopping Mall. In this case the escalators and   Upper Roof Level  Suspended
 panoramic glass elevators with minimum capacity of 10 people      Element
 shall be provided as connection elements between the floors.  ≥ 1.5 m
                                Setback
 11.3.3   No second mezzanine shall be permitted within the ground floor   ≤ 3.6 m
 space if the original mezzanine floor had been detached and   ≥ 1.1 m  Rooftop Level  Gymnasium
 used independently.

 11.3.4   No balconies or terraces shall be permitted in the mezzanine
 floor.
                          Last Floor







                                      Figure-33   Rooftop



                     11.4.3    It is permitted to add some pergolas or swimming pools,
                            gymnasiums  and  related  facilities  on  the  rooftop  If  the  plot
                            area exceeds 250.0 square meters, for all building types,
                            except the residential villas, industrial buildings and staff
                            accommodations.


 94                                                                      95
   91   92   93   94   95   96   97   98   99   100   101