SEcTION: 11  BUILDING STORIES /FLOOR TYPES                                          SEcTION: 11  BUILDING STORIES /FLOOR TYPES



                11.3  MEZZANINE                                                                     11.4  ROOFTOP


                     That portion of a floor which is an intermediate level placed within                Part of a full floor situated above the Last floor of the building and
                     building  floors and having occupy-able space above and below its floor.            normally being used for accommodating elevator machinery, mechanical/
                     Its functional use may either be complementary and belonging to the                 electrical rooms, water tanks, pergolas, swimming pools and gymnasiums
                     ground floor or independent functional use similar to typical floor or may          in addition to services associated with them.
                     be used for services.
                                                                                                         11.4.1   All buildings must feature either some form of sloped roof or
                     11.3.1   The mezzanine floor shall be permitted to be used 100%                            parapets screening a flat roof.
                            independently if it is used as parking space for cars, or as
                            extension to the main function of the whole building, which is               11.4.2   A flat roof, if specified, shall be screened with parapets on all
                            used for one common purpose.                                                        sides of the building. Parapets shall be at least 1.1 meter in
                                                                                                                height from average roof floor finished level / FFL. (figure -33)
                     11.3.2   The mezzanine floor can be used for commercial purposes that
                            are 100% independent, in case of using the ground floor and the
                            mezzanine as a Shopping Mall. In this case the escalators and                                             Upper Roof Level  Suspended
                            panoramic glass elevators with minimum capacity of 10 people                                                               Element
                            shall be provided as connection elements between the floors.                            ≥ 1.5 m
                                                                                                                   Setback
                     11.3.3   No second mezzanine shall be permitted within the ground floor                                                               ≤ 3.6 m
                            space if the original mezzanine floor had been detached and               ≥ 1.1 m    Rooftop Level         Gymnasium
                            used independently.

                     11.3.4   No balconies or terraces shall be permitted in the mezzanine
                            floor.
                                                                                                              Last Floor







                                                                                                                          Figure-33   Rooftop



                                                                                                         11.4.3    It is permitted to add some pergolas or swimming pools,
                                                                                                                gymnasiums  and  related  facilities  on  the  rooftop  If  the  plot
                                                                                                                area exceeds 250.0 square meters, for all building types,
                                                                                                                except the residential villas, industrial buildings and staff
                                                                                                                accommodations.