SEcTION: 6  BUILDING/DEVELOPMENT CONTROL FACTORS                                    SEcTION: 6  BUILDING/DEVELOPMENT CONTROL FACTORS



                    6.2.2  The gate/reference level of all building types shall not be less than        6.2.5  The internal clear (net) height of each floor for different building
                          0.30 meter above the approach road/s edge level and in case of                      types is the distance from the finished floor level to the finished
                          inclined longitude road, stepped ground level to be used to achieve                 ceiling level or any suspended element from ceiling as shown in
                          above relation between gate and road levels.                                        table-1: (figure -10)

                    6.2.3  The ground finished floor level (GFFL) for all building types shall                                                       Maximum Net
                                                                                                                                        Minimum Net
                          not exceed 1.2 meter above the adjacent road edge level except for         Section No Building Types          Height (meter)  Height (meter)
                          residential villas which shall not exceed 1.5 meter. (figure-8)
                                                                                                       6.2.5.1  Residential Type            2.7         4.2
                    6.2.4  In case of a plot located on two different road levels, the ground
                                                                                                       6.2.5.2  Commercial Type
                          finished floor level (GFFL) for all building types shall not exceed 0.45
                          meter from high road edge level and 1.2 meter from the low road edge                           Ground floor       3.0         4.2
                          level. While (GFFL ) for villas shall not exceed 1.5 meter from the road
                                                                                                                         Ground floor with
                          edge level leading to the main entrance. (figure-9)                                 Shops and   Half Mezzanine    2.4         4.2
                                                                                                           a)
                                                                                                              Showrooms
                                                                                                                         Half Mezzanine     2.4         3.0
                                                        For All Building Types;                                          Full Mezzanine     2.6         3.0
                                                        GFFL ≤ 0.45 m above Road 1
                                                        GFFL ≤ 1.2 m above  Road 2                        b)  Office                        2.5         3.0

                                                                                                           c)  Commercial Centers           4.2         6.0
                                                        For Villa;                                     6.2.5.3  Industrial Type
                                  GFFL                  GFFL≤ 1.5 m  from main
                                                        entrance road level
                                                                                                           a)  Warehouse and Factories      4.0         9.0
                  Road 1                                                                               6.2.5.4  Educational Type
                 High Level
                                                                                                              Schools, Nurseries and Kindergar-
                                                                   Road 2                                  a)                               3.0         4.2
                                                                  Low Level                                   tens
                                                                                                       6.2.5.5   Religious Type

                                                                                                                                                   According to the
                                                                                                           a)  Mosque                       3.6    design and capacity
                             Figure-9   Ground Finished Floor Level (GFFL)                                                                         of the mosque
                               for Plot Located on Different Road Level
                                                                                                       6.2.5.6  Covered Parking Area        2.4         3.0

                                                                                                             Table-1 Internal Clear Height for Different Building Types