SEcTION: 19  REFUSE DISPOSAL REQUIREMENTS                                           SEcTION: 19  REFUSE DISPOSAL REQUIREMENTS




                           ≥ 0.3 m                         ≥ 0.3 m                                  19.2  GARBAGE chUTES

                                                                    Garbage                              19.2.1   For buildings with more than three stories a garbage chute shall
                                                                    Trolleys
                                                                    Capacity                                    be installed.
                                                                    2.5 *(m3)
                                                                                                         19.2.2   The materials for the garbage chute shall be non-corrosive, non-
                                                    2.04 m                                                      combustible, prevent dampness, and have smooth inner surface.

                                                      1.48 m                                             19.2.3   The minimum chute diameter shall be 0.6 meter inside the small
                                                                                                                room of not less than 0.9 x 0.9 meter in size. Door of minimum
                                                                      ≥ 0.3 m                                   0.8 meter wide, opening outwards with an automatic closing

                                                      1.22 m                                                    mechanism shall be fitted to all typical floors.
                                            Internal
                                            Corridor  1.26 m         Garbage                             19.2.4   For plot area less than 1500.0 square meters, the garbage chute
                                                                     Trolleys
                                                                     Capacity                                   can be replaced by a small room 1.8 x 1.2 meter on each floor in
                                            ≥ 1.2 m                  1.1 *(m3)                                  addition to the main garbage room on the ground floor.
                    ≥ 0.6 m                ≥ 1.8 m                                                              The doors shall be 0.9 meter minimum width opening outwards
                                                                                                                and shall have an automatic door closing mechanism and
                                                                                                                mechanical ventilation.
                                 ≥ 1.2 m                                                                 19.2.5   Service elevator located separately from the main building’s

                                                                                                                elevators lobby, close to the garbage room at the ground floor
                                                                                                                can replace the garbage chute in addition to the small room in
                                                                                                                each floor of not less than the size of the service elevator.
                                               Ramp
                                                                                                         19.2.6   The owner of the building or the authorized representative is
                                          slope ≤ 8%                                                            responsible for cleaning the building internally and externally,
                                                                                                                together with the surrounding area to the public road.
                               Figure-80   Garbage Room Mearsurements
                                                                                                         19.2.7   If the location of the chute is far from the road surrounding the
                                                                                                                plot, the garbage collection room shall be located near to the
                                                                                                                road, or alleyway in case of non- existence of a road.

                                                                                                         19.2.8   Active chemical waste, liquids and /or any other hazardous toxic
                                                                                                                materials shall not be place inside the garbage dumpsters or
                                                                                                                containers.