Page 89 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 89

SEcTION:10  EXTERNAL BUILDING ELEMENTS AND PROJECTIONS                              SEcTION:10  EXTERNAL BUILDING ELEMENTS AND PROJECTIONS



                                                                                                    10.4  PERGOLAS

                                                                         e                               10.4.1   It is permitted to build pergolas in the unoccupied /setback
                                                       h
                                                 x                                                              areas of the plot, with the minimum transparency percentage
                                                                                                                of 50% of its total area, with maximum height of 3.0 meters.
                                                                           s
                                                                                                                (figure -31)

                                                                                                                                    ≥50% transparency
                                                          t
                                                                                                                                    area
                                           a                        (e-h)
                                                              x = a
                                                                     s
                                                                                                                         ≤3.0 m                         Building
                             a - step depth   h - wall height  x - wall depth
                             e - eye level    s - storey height  t - terrace depth                                    Plot Limit
                             Figure-30    Privacy Considerations for Stepped Terraces
                                                                                                                                    Setback
                                                                                                                           As per DCR for related Business Unit
                     10.3.3  The minimum setback of terraces shall be as per DCR of related
                            business unit and shall be at least 3.0 meters.                                          Figure-31   Transparent Pergola within Setback

                     10.3.4  It is permitted to close and add the existing terraces, in order            10.4.2   It is permitted to build pergolas as a shading device for the
                            to be annexed to the internal habitable spaces, according to the                    swimming pools, on rooftop floor, according to the following:
                            following conditions:                                                               a)  Minimum setback of 1.5 meter from the roof edge.
                            a)  The width of the approach road exceeds 10.0 meters.                             b)  Maximum projection of 1.5 meter from the pool edge.
                            b)  The length of the total terrace at any floor shall not exceed                   c)  Maximum height of 3.0 meters above the pool level.
                              50% of the total length of the building façade.                                     (figure -32)
                                                                                                                                    ≤1.5 m        Pergola
                            c)  The habitable space area, excluding additional terrace
                              area, conforms  to the  minimum habitable  space  area                                                                ≥1.5 m
                                                                                                                           ≤3.0 m.
                              requirements.                                                                                                        Setback
                     10.3.5   Empty side of the terrace and steps higher than 1.0 meter shall                                      Swimming Pool Level          ≥1.1 m
                            have a protective barrier or balustrade whose minimum height is
                            1.1 meter.
                                                                                                                          Swimming Pool
                     10.3.6   Railing provision for terraces shall be as mentioned in clause
                            10.1.13.
                                                                                                                      Figure-32   Pergola over Swimming Pool on Rooftop


           88                                                                                                                                                89
   84   85   86   87   88   89   90   91   92   93   94