Page 86 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 86

SEcTION:10  EXTERNAL BUILDING ELEMENTS AND PROJECTIONS  SEcTION:10  EXTERNAL BUILDING ELEMENTS AND PROJECTIONS



                     10.1.9  Open balconies require a protective screen on the side facing the
 Canopy only
                            prevailing wind. (figure -28)
 Top of Roof  X(m)  X1(m)
 1.8 18.0 & above
 Balcony /  1.2  (12.0-15.0)
 ≥ 0.9 m  Canopy  1.5  (15.0-18.0)

 1.0  (10.0-12.0)
 ≥ 1.10m  Canopy  only  0.5  (6.0-10.0)
 below 6.0
 0.3


 X=Projections (Balcony/Canopy)









 ≥ 6.0m                        Figure-28   Open Balcony with Screen

 X1 = Road Width

                     10.1.10  Balconies’ balustrades shall be made with vertical rods rather
                            than horizontally constructed, to prevent children from climbing.
 Road
 Level               10.1.11  For residential buildings, hotels, and hotel serviced apartments
                            up to 6 floors, the minimum height of the external balcony railing
                            shall be 1.1 meter, with maximum clearance of 0.1 meter among
 Plot Limit                 the vertical rods of the railing. While above 7 floor, balcony railing
                            shall be consist of solid panels.

 Figure-27   Building Projections (Balconies / Canopies) over Road  10.1.12  A privacy partition shall be installed between connected balconies.

                     10.1.13  For other types of buildings, the minimum height of the internal
                            and external balcony railing shall be 1.1 meter, with maximum
 10.1.8   Balconies  shall  be  free  from  unpleasant  elements  such  as
 laundry, storage or antenna.  clearance among the vertical rods of the railing. 0.125 meter.




 84                                                                      85
   81   82   83   84   85   86   87   88   89   90   91