Page 64 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 64

SEcTION  8  SPACE TECHNICAL REQUIREMENTS  SEcTION: 8  SPACE TECHNICAL REQUIREMENTS







 8.1   SPAcE AREAS AND DIMENSIONS  ≥ 3.0 m                 ≥ 3.0 m

 The minimum floor area and clear dimension of any space in different
 types of building shall be as below table -2: (figure -15 and 16)

 Minimum Floor Area  Minimum Dimension
  Space
 (square meters)  (meter)     *A
                                                          O 1.25 m
 Retail   12.0   2.4
 Office  10.0   2.5
                             1.0 m
 Residential (bed, living, etc)  12.0   3.0                  *A

 Kitchen  6.0   2.0
 Studio without Facilities  15.0   3.5    Dining
                                        *A ≥ 12.0 m²
 Pantry  4.5   1.8
                               ≥ 3.0 m
 Servants / Guard Rooms and    6.5   2.1
 similar Service Rooms
 Bathroom   4.5   1.8

 Bathroom with Shower only  3.0   1.6
                                                             ≥ 3.0 m
 Lavatory  2.0   1.2
                   ≥ 3.0 m

 Table-2 Minimum Areas and Dimensions via Different Space Types   *A
                     ≥ 0.9 m

                                                ≥ 3.0 m

                               ≥ 1.2 m  Dressing  ≥ 0.9 m          *A
                                     Room




                                                             Bedroom
                       Bedroom with Dressing Room           *A ≥ 12.0 m²


                     Figure-15    Minimum Areas and Dimensions for Residential Spaces

                *A = Floor Area
 62                                                                      63