Page 63 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 63
SEcTION 8 SPACE TECHNICAL REQUIREMENTS SEcTION: 8 SPACE TECHNICAL REQUIREMENTS
8.1 SPAcE AREAS AND DIMENSIONS ≥ 3.0 m ≥ 3.0 m
The minimum floor area and clear dimension of any space in different
types of building shall be as below table -2: (figure -15 and 16)
Minimum Floor Area Minimum Dimension
Space
(square meters) (meter) *A
O 1.25 m
Retail 12.0 2.4
Office 10.0 2.5
1.0 m
Residential (bed, living, etc) 12.0 3.0 *A
Kitchen 6.0 2.0
Studio without Facilities 15.0 3.5 Dining
*A ≥ 12.0 m²
Pantry 4.5 1.8
≥ 3.0 m
Servants / Guard Rooms and 6.5 2.1
similar Service Rooms
Bathroom 4.5 1.8
Bathroom with Shower only 3.0 1.6
≥ 3.0 m
Lavatory 2.0 1.2
≥ 3.0 m
Table-2 Minimum Areas and Dimensions via Different Space Types *A
≥ 0.9 m
≥ 3.0 m
≥ 1.2 m Dressing ≥ 0.9 m *A
Room
Bedroom
Bedroom with Dressing Room *A ≥ 12.0 m²
Figure-15 Minimum Areas and Dimensions for Residential Spaces
*A = Floor Area
62 63