                     16.1.2  VILLAS ANNEXES: (figure -70)                                                          Height ≤ 4.2 m
                                                                                                                               Adjacent Neighbor   Plot
                            a)  It is permitted to build annexes to residential villas with                                                        Limit
                              maximum height limited to ground floor only and without any                         A1 = Annex 1
                              set back from the plot boundary.                                                       Area
                                                                                                                           Corridor or Covered Passage
                            b)  It can be used as private garages, servants quarter, external                   ≥ 3.0 m          ≤ 3.0 m
                              kitchen or as a sitting room (Majlis ), according to the following                                   wide
                              conditions:
                                                                                                           Adjacent                                    Adjacent
                                The maximum height shall not exceed 4.2 meters from the                   Neighbor            A = Villa Area          Neighbor
                                 adjacent neighbors and 4.5 meters from the approaching
                                 road or alleyway.
                                                                                                                                             ≥ 3.0 m     Height ≤ 4.5 m
                                The minimum set back shall be 3.0 meters between the
                                 annex and the main villa.
                                                                                                                                              A2 = Annex 2
                                The annex configuration shall be in a form of a row,                                                           Area
                                 attached  to  the  plot  boundary,  or  with an  adequate                    Plot               Road               Only allowable
                                                                                                              Limit                                 opening is for a
                                 setback to allow for natural ventilation and lighting for the
                                                                                                                                 A1 + A2 ≤ 50% A    garage gate
                                 habitable spaces, or in order to install air conditioners.
                                                                                                                            Figure-70    Villas Annexes
                            c)  Annexes shall be used to serve the main building only. They
                              shall not be used as independent units or for commercial
                              purposes.

                            d)  Its roof shall be limited for water tanks and air conditioner
                              equipments.

                            e)  It is forbidden to build a main staircase leading to its roof, if it
                              is located next to the adjacent neighbors.

                            f)  The annex may be connected to the main building by a covered
                              passage or corridor with maximum width of 3.0 meters and
                              same height as the annex.
                            g)  The area of the annexes shall not exceed 50% of the main
                              villa’s area.