Page 159 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 159

SEcTION: 16  BUILDING OR DEVELOPMENT TYPES                                          SEcTION: 16  BUILDING OR DEVELOPMENT TYPES



                     16.1.3  STAFF ACCOMMODATIONS                                                               k)  Bus parking space, to cater for 50% of the occupants at one
                                                                                                                  time shall be provided.
                            a)  Each person is required to have 3.8 square meters floor area
                              within the room.                                                                  l)  Adequate water coolers shall be provided with maximum
                                                                                                                  travel distance of 30.0 meters interval.
                            b)  The number of floors and setbacks shall be according to the
                              DCR of related business unit.                                                     m) The buildings / structures must be at least  6.0 meters away
                                                                                                                  from kitchens, workshops and stores.
                            c)  The minimum internal setbacks between the buildings should
                              be 6.0 meters, within the property line.                                          n)  Means of escape travel distance should not exceed 15.0
                                                                                                                  meters in one direction and 30.0 meters in two directions
                            d)  One lavatory, one washbasin, with one shower is the minimum
                              requirement for every 10 occupants and laundry tray or tub for                      from any point to the main road of the site.
                              every 30 persons.                                                                 o)  If double-deck bunks are used, the minimum clear distance
                                                                                                                  between the lower and upper bunk must not be less than 0.7
                            e)  In case construction is deemed to be in phases then, the
                              minimum percentage construction for the first phase of                              meter. Triple-deck bunks are strictly prohibited.
                              construction shall be adequate enough to accommodate 50%                          p)  Adequate first aid facilities verified by E.H.S. must
                              of the staff total number as per documents relating to the plot                     be maintained and be made available in every staff
                              allocation.                                                                         accommodation  for  the  emergency  treatment  of  injured
                                                                                                                  persons. Such facilities must be under the supervision of a
                            f)  It is forbidden to direct room door openings into the road or
                              alleyway and the main entrance shall be open within the plot                        person trained to administer first aid and must be readily
                              limits.                                                                             accessible at all times.

                            g)  A room with independent services (non-collective) for the
                              supervisors at the rate of one room per 40 occupants.

                            h)  There shall be one or more kitchens for preparing food, and a
                              dining room, which can accommodate minimum of 1/3 of the
                              occupants at one time. Minimum floor space in eating area
                              shall not be less than 1.2 square meter per person. The design
                              and furnishings of the kitchen and dining room must meet all
                              E.H.S. requirements.
                            i)  Indoor recreational facilities shall be at a minimum of 1/4 of
                              total net area.
                            j)  There shall be a garbage room or an open collection point for
                              garbage containers within the perimeter of the plot, according
                              to the rules on garbage rooms set out in these regulations.