Page 128 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 128

SEcTION: 14  ACCESS RAMPS REQUIREMENTS  SEcTION: 14  ACCESS RAMPS REQUIREMENTS



 14.2  RAMPS FOR PUBLIc AND PEOPLE WITh DISABILITY  14.3.1   The minimum width for service access ramps shall be 1.2 meter,
                            with slopes not greater than 8%.
 All building types except the private villas shall require accessible ramps
 for people with disability. Public ramps are required for specific building   14.3.2   No handrail is required if the slope of the ramp is 5% or less and
 such as: schools, airports and buildings with similar activity. Refer to   if the maximum landing level is 1.0 meter.
 the Authority’s related code on the minimum requirements for above
 mentioned ramps width, slope, location, handrail, etc.  14.3.3   If  a ramp  slope  is  greater  than  5%,  then  handrail  will  be
                            required.

 14.3  SERVIcE RAMPS  14.3.4   Landing platforms for all building entrance doors shall be on
 Ramp exclusively for services such as: forklifts, garbage trolleys, etc   level and sloped if drainage is required.
 (figure -54)        14.3.5   Landing platforms shall be at least 1.2 meter deep if doors swing

                            inwards, and 1.5 meter deep if doors swing outwards.

 ≥1.2 m  ≥ 1.5 m     14.3.6   If the vertical height requires two ramps to achieve the properly
                            graded slope, the ramps shall not be longer than 10.0 meters
                            and shall be separated by a level-landing platform of at least 1.2
                            meter long with 90 or 180-degree turns.
 Slope ≤ 8%  Slope ≤ 8%  14.3.7  The ramp surface should be hard and non- slippery.



 ≥1.2m  ≥1.2m


 ≥ 1.2 m



 ≤10.0 m
 ≥ 1.2 m









 ≤10.0m
 ≥ 1.20 m
 ≥ 1.2 m

 Figure-54   Service Ramp Requirements


 126                                                                     127