SEcTION: 14  ACCESS RAMPS REQUIREMENTS                                              SEcTION: 14  ACCESS RAMPS REQUIREMENTS



                14.2  RAMPS FOR PUBLIc AND PEOPLE WITh DISABILITY                                        14.3.1   The minimum width for service access ramps shall be 1.2 meter,
                                                                                                                with slopes not greater than 8%.
                     All building types except the private villas shall require accessible ramps
                     for people with disability. Public ramps are required for specific building         14.3.2   No handrail is required if the slope of the ramp is 5% or less and
                     such as: schools, airports and buildings with similar activity. Refer to                   if the maximum landing level is 1.0 meter.
                     the Authority’s related code on the minimum requirements for above
                     mentioned ramps width, slope, location, handrail, etc.                              14.3.3   If  a ramp  slope  is  greater  than  5%,  then  handrail  will  be
                                                                                                                required.

                14.3  SERVIcE RAMPS                                                                      14.3.4   Landing platforms for all building entrance doors shall be on
                     Ramp exclusively for services such as: forklifts, garbage trolleys, etc                    level and sloped if drainage is required.
                     (figure -54)                                                                        14.3.5   Landing platforms shall be at least 1.2 meter deep if doors swing

                                                                                                                inwards, and 1.5 meter deep if doors swing outwards.

                                  ≥1.2 m            ≥ 1.5 m                                              14.3.6   If the vertical height requires two ramps to achieve the properly
                                                                                                                graded slope, the ramps shall not be longer than 10.0 meters
                                                                                                                and shall be separated by a level-landing platform of at least 1.2
                                                                                                                meter long with 90 or 180-degree turns.
                                  Slope ≤ 8%        Slope ≤ 8%                                           14.3.7  The ramp surface should be hard and non- slippery.



                      ≥1.2m             ≥1.2m


                                            ≥ 1.2 m



                                                      ≤10.0 m
                                                                       ≥ 1.2 m









                              ≤10.0m
                                               ≥ 1.20 m
                        ≥ 1.2 m

                                  Figure-54   Service Ramp Requirements