Page 54 - Dubai Universal Design Code
P. 54
5.10. Elevators
Elevators placed in public areas must be accessible from the ground floor.
An elevator, lift or platform should be provided in every building with more than one
floor.
The requirements to be fulfilled by an accessible elevator are:
1. The dimensions should be appropriate for the intended number of users and in all
instances equal to or bigger than the specified minimum dimensions of the cabin.
2. Depending on the number and position of the doors, dimensions are shown in the
following table:
Dimensions of the cabin (wide x deep)
Minimum Recommended
One door cabin 1200 mm x 1500 mm 1500 mm x 1500 mm
Cabin with two opposing doors 1200 mm x 1500 mm 1500 mm x 1500 mm
Cabin with two doors in 90° angle 1500 mm x 1500 mm 2000 mm x 2000 mm
Table 5. Dimensions of elevator cabins in public areas
3. The elevator doors of the floor and the cabin must be automatic, have a minimum
width of 900 mm, minimum height of 2000 mm, and present colour contrast against
the walls.
4. In front of the elevator access door and in front of the hall call button there should be
a minimum clear manoeuvring space of 1500 mm x 1500 mm.
5. Elevator call buttons shall be located at a height between 900 mm and 1200 mm.
6. Floor indicators shall be located at a height of 1830 mm.
7. A mirror shall be placed inside the elevator on the wall opposite to the door, from the
handrail height upward, covering the full back panel.
8. At least two handrails shall be placed at a height of 900 mm ± 100 mm from the
floor.
53