Page 284 - Dubai Universal Design Code
P. 284
Level changes
Facility/Building…………………………….
Sheet Number ………
Space/Floor …………………….…………..
YES N/A
NON Observations
Stairs
Landing with same width of stair and a
length ≥ 1200 mm
Empty space with height < 2200 mm
under the stair is protected
Handrails
300 mm horizontal extension at its
ends
Presence of intermediate handrail for
stairs larger than 2400 mm
Height of 900 mm
Additional handrail at a height between
650 - 750 mm
Circular section of 30 - 40 mm
separated from the wall ≥ 40 mm
Contrast of 30 LRV against its
background
Elevators
Present in buildings with more than
one floor
Dimensions shall comply:
One door - 1200 x 1500 mm
Two opposing doors - 1200 x 1500 mm
Two doors in 90° - 1500 x 1500 mm
Automatic doors with a width of 900
mm and colour contrast against walls
283