Page 283 - Dubai Universal Design Code
P. 283

Level changes

                     Facility/Building…………………………….
                                                                                 Sheet Number ………
                     Space/Floor …………………….…………..

                                                                  YES   N/A
                                                                            NON      Observations

                   Ramps

                   Corridors in landings with no less than
                   1200 mm width

                   Doors at ≥ 1500 mm from start of each
                   ramp run
                   Stairs


                   With an alternative elevator


                   Steps rises between 150 - 176 mm

                   Steps stair treads between 300 - 340
                   mm

                   Steps rise (R) and Treat (T) fulfil:

                   650 mm < 2R + T < 700 mm

                   No open risers or discontinued treads


                   Steps with nosing ≤ 25 mm


                   30 mm from the step edge shall
                   present a reflectance contrast of 30
                   LRV


                   Steps with same height with a ± 4 mm
                   tolerance


                   Stair flights steps number between 3
                   and 12


                   Usable width ≥ 1200 mm


                   Illumination at top and bottom ≥ 200lux