Page 77 - Building Regulation Design Guidelines - Architecture Book (Blue Code)
P. 77

SEcTION: 9  OPENINGS REQUIREMENTS                                                   SEcTION: 9  OPENINGS REQUIREMENTS



                                  to the specifications and conditions approved by the                         9.4.2.2  Open Kitchens: It is permitted to build kitchens that occupy
                                  Authority. (figure -23)                                                             part of the common spaces (halls or living areas), without
                                                                                                                      providing ventilation shafts, regardless of the building height,
                                             ≥ 0.9 m
                                                                                                                      and as long as the Kitchens are located opposite to the main
                                                                                                                      openings of such common spaces.  Total depth shall not
                                                                                                                      exceed three times of common space width, and is provided
                                         *A           Kitchen                                                         in accordance to the specifications and conditions as approved
                                                                                                                      by the Authority. (figure-24)
                                                         ≥ 2.0 m


                                              *W                                                                                           ≥  2.0 m



                                                                                                                              *A2    Kitchen



                                             Shaft       ≥ 3.0 m



                                             ≥ 3.0 m


                                                                                                                              Living
                                              *W
                                                                                                                               *A2       Depth


                                                 *A
                                                Kitchen  ≥ 2.0 m

                                                                                                                              Width

                                      ≥ 0.9 m                                                                                     *W
                                  *A ≥ 6.0 m²  *W ≥ 5% A
                                                                                                                      *A1 ≥ 6.0 m²   *W ≥ 10% (A1 + A2)
                                                                                                                      Depth ≤ 3 Width
                                        Figure-23   Shaft for Closed Kitchen
                                                                                                                          Figure-24  Open Kitchen

                *A = Floor Area / *W= Window Area                                                   *A = Floor Area / *W= Window Area
           76                                                                                                                                                77
   72   73   74   75   76   77   78   79   80   81   82