SEcTION: 9  OPENINGS REQUIREMENTS                                                   SEcTION: 9  OPENINGS REQUIREMENTS



                9.4  cOURTYARDS AND ShAFTS:                                                                    9.4.1.2  In residential apartments, natural lighting and ventilation
                                                                                                                      for the maid’s room can be provided through the
                     The minimum area of the courtyard and shaft for the natural lighting and                         shafts, which shall be no less than 3.0 x 3.0 meters,
                     ventilation requirements shall be as follows:
                                                                                                                      regardless of the building height. If the building
                     9.4.1  Habitable Spaces:                                                                         exceeds  ground  floor  plus  7  typical  floors,  Mechanical
                           9.4.1.1   In case that the courtyard is common for many habitable                          ventilation shall be provided in accordance to the
                                  spaces and floors, the minimum area for courtyard shall                             specifications and conditions approved by the Authority.
                                  be square of 1/3 of the total floors height overlooking                             (figure-22)
                                  at the courtyard and with minimum width of 6.0 X 6.0
                                  meters. (figure-21)                                                                 ≥ 3.0 m                    ≥ 2.1 m


                                         *L ≥ 6.0 m
                                                H-Floor Height
                                        Court
                                        Yard

                                                                                                      ≥ 3.0 m          Court                *W    Maid's
                                                                                                                        Yard
                                                                                                                                                   Room




                                                                                                                                                    *A


                                                                                                         *A ≥ 6.50 m²  *W ≥ 10% A
                                                                                                                    Figure-22   Shaft for Maid's Room
                                            Court Yard
                                       *A             *L ≥ 6.0 m                                               9.4.1.3  Additional natural ventilation and lighting are required
                                            *L ≥ 6.0 m                                                                for rooms whose depth is more than three times its width.
                                                                                                                      An opening or a shaft shall be in a minimum of 5% of the
                                                                                                                      space area.
                                                                                                         9.4.2  Service Spaces:
                                                                                                               9.4.2.1  Closed Kitchens:  The minimum dimension of the shaft
                          1
                       *A=( X H) 2  and *L ≥6.0 m                                                                     shall be 3.0 x 3.0 meters regardless of the building height.
                          3
                                                                                                                      Mechanical ventilation shall be provided, if the building
                             Figure-21   Court Yard for Habitable Spaces
                                                                                                                      exceeds ground floor plus 7 typical floors in accordance
                *A = Floor Area / *L= Court yard Width                                              *A = Floor Area / *W= Window Area