SEcTION: 21  UTILITY SERVICES  SEcTION: 21  UTILITY SERVICES



 21.4.3   Every exposed roof, canopy or building shall be finished with a   21.7  ELEcTRIcITY/LIGhTING AND TELEPhONE INSTALLATIONS
 gradient of not more than 2% and not less than 1.4% in order to
 direct the rainwater to suitable channels, gutters, and outlets or   21.7.1   Electricity, Lighting & Telephone requirements shall comply with
 down pipes.                the Authority’s relevant code.

 21.4.4   All rainwater shall be either drained into a specially constructed   21.7.2   Electrical rooms in buildings shall satisfy the following
 soak away or into the approach  road to prevent dispersal of   requirements:
 surface water towards adjacent plots.
                            a)  Proposed location  and dimensions  of the electrical  room
                               shall be subject to approval by the related Authority.
 21.5  GAS FAcILITIES
                            b)  The Electrical transformer room may be situated in the
 21.5.1   Central gas supply and gas cylinder requirements shall comply   setback area as such transformer provides a public service
 with the Authority’s relevant code.   to the buildings in the area.
 21.5.2   Gas cylinders shall be kept in a covered, well-ventilated area   21.7.3   Telephone requirements:
 outside the kitchen or the habitable spaces.
                            a)  An appropriate area or areas shall be set aside for the
 21.5.3   The  gas  cylinder  storage in  public  buildings  shall  be well   location of termination boxes, distribution frames equipment
 ventilated, easily accessible to facilitate changing the empty   etc. This may vary from a vacant wall in a secure room to a
 cylinders and to be isolated, in case of fire.  complete room depending on the telephone requirements of
                               the building.
 21.5.4   All gas connections  shall be confirmed  to the  standard
 specifications approved by the Authority.  b)  A comprehensive system of horizontal and vertical cable
                               trays and/ or conduits from the external cable termination
                               point to telephone points throughout the building shall be
 21.6  VENTILATION AND AIR cONDITIONING  provided.

 21.6.1   Design and installation of all air conditioning and ventilation
 systems shall be in accordance with current guidelines of the
 Authority’s relevant code.

 21.6.2   Architectural features should be introduced in the elevations/
 facades in order to conceal the air conditioning equipment
 from  the  public  eye.  The  minimum  distance  between  any  air
 conditioning unit and the neighbor’s boundary shall be 0.9
 meter.