4.  Cleaning products should not leave a residual odor


               5.  Allergy considerations shall be observed

               11.2.12.  Infrastructure interface

               The interface of the train with the platform shall comply with the following:


               1.  A straight line platform for the whole length of the train.


               2.  The platform screen doors at full height

               3.  Tactile and high contrast warning strips along the length of the platform edge facing
                   the train.

               4.  A horizontal gap between the train and the platform not to exceed 50 mm

               5.  A vertical gap not to exceed 15 mm

               6.  “Watch the Gap” sign on the platform at all door entrances and on and train doors.


               11.2.13.  Emergency and evacuation


               Emergency and evacuation information shall be provided in audio and visuals format in
               real time.

               Staff training and drills shall be provided for emergency and evacuation situations to
               assist person with mobility and sensory impairments.