Page 72 - Dubai Universal Design Code
P. 72
The number of accessible toilets shall follow the table 7.
NUMBER OF ACCESSIBLE TOILETS
Use of the Building, Minimum Number of Toilets
establishment or area
Any public use 1 Accessible toilets for each gender should be
provided in every floor being at least 10% of the
total number of toilets in every block or 1
independent accessible toilet for both genders
1 accessible toilet within a 150 meters distance
from any part of the building
Table 7. Number of Accessible Toilets
The following table indicates the minimum dimensional parameters required for
accessible toilets:
Minimum dimensions for accessible toilets
Dimensions of circulation spaces
Corridor widths in toilets, showers, lockers spaces, etc. 1200 mm
Manoeuvring turning space diameter 1500 mm
Accessible toilets and cubicles conditions
Manoeuvring space diameter between 0 and 700 mm height 1500 mm
free of obstacles
Lateral interaction space On both sides
Table 8. Minimum dimensional parameters for accessible toilets
71