The number of accessible toilets shall follow the table 7.




                                        NUMBER OF ACCESSIBLE TOILETS

               Use of the Building,                           Minimum Number of Toilets
               establishment or area


                 Any public use                    1 Accessible toilets for each gender should be
                                                   provided in every floor being at least 10% of the
                                                   total number of toilets in every block or 1
                                                   independent accessible toilet for both genders

                                                   1 accessible toilet within a 150 meters distance

                                                   from any part of the building


                                          Table 7. Number of Accessible Toilets

               The following table indicates the minimum dimensional parameters required for
               accessible toilets:



                Minimum dimensions for accessible toilets

                 Dimensions of circulation spaces


                 Corridor widths in toilets, showers, lockers spaces, etc.                1200 mm

                 Manoeuvring turning space diameter                                       1500 mm


                 Accessible toilets and cubicles conditions

                 Manoeuvring space diameter between 0 and 700 mm height                   1500 mm
                 free of obstacles

                 Lateral interaction space                                              On both sides


                            Table 8. Minimum dimensional parameters for accessible toilets