Page 309 - Dubai Universal Design Code
P. 309

Internal corridors, alarms and means of egress, gender equality, storage
                   facilities and lockers, accessible dressing and changing rooms, first aid
                   facilities and balconies

                   Facility/Building …………………………….                                Sheet Number ………
                   Space/Floor …………………………………

                                                                 YES   N/A
                                                                           NON       Observations

                   Internal corridor

                   Width ≥ 1000 mm

                   In direction changes a manoeuvring
                   space of 1200 mm


                   Tactile warning surface in any change
                   of level

                   Illumination ≥ 60 lux


                   Alarms and means of egress


                   Audio and visual emergency alarms


                   Visual emergency alarm with 30
                   flashes per second

                   Accessible means of egress marked
                   with accessible signage


                   Gender equality


                   In case of segregated use by gender,
                   same level of accessibility for both
                   genders

                   Storage facilities and lockers

                   20% of shelves or lockers are in a
                   reaching height distance between 600 -
                   1200 mm





                                                                                                          308