12.4.  Group travel


               12.4.1.     Group vessel


               A single level vessel shall be equipped with the following features:


               1.  Gangway/ramps at service doors.

               2.  Flip seats to make room for additional wheelchair spaces.


               3.  At least 4 forward-facing wheelchair securement systems.

               4.  Onboard information system.


               12.5.  Vessel infrastructure interfaces


               12.5.1.     Gangways


               Gangways connecting the building and/or the berth shall conform to the following
               requirements:


               1.  Be at least 2000mm wide with handrails on each side.

               2.  There should be an upper and lower handrail on each side of the gangway. The
                   upper handrail should be 875-925 mm and a lower handrail 600-750 mm above the
                   gangway surface to the top of the handrail. Handrails shall have a circular section
                   with an outside diameter of 30 to 40 mm.

               3.  Surfaces shall be non-slip and non-reflective with a warning strip in contrasting color
                   at each end of the gangway of 300 mm wide across the width of the gangway.


               4.  When intersecting with the berth surface a beveled edge of maximum 15 mm in
                   height shall be provided.